COMPRESSOR

 

Capacity  :  100 CFM

Pressure  :  6 - 7 bar

 

Separate air receiver tank of capacity 1,000 litres is recommended

 

ELECTRICALS

 

The customer shall provide clean power supply to the machine. Three-phase voltage with following fluctuations should be made available.

 

a) For countries with mains supply of 3×400V / 50Hz or 3×415V / 50Hz or 3×420V / 50Hz with separate neutral and earth. The neutral wire must be fully loadable.

Admissible fluctuations

Voltage: -10% to +5%

Frequency: +/- 2%

 

b) For countries with mains supply of 3×380V / 50Hz or 3×380V / 60Hz with separate neutral and earth. The neutral wire must be fully loadable.

Admissible fluctuations

Voltage: -5% to+10%

Frequency: +/- 2%

 

c) For countries with mains supply of 3×440V / 60Hz with separate neutral and earth. The neutral

wire must be fully loadable.

Admissible fluctuations

Voltage: -10% to +5%

Frequency: +/- 2%

 

In case the voltage variation is beyond the limits as specified above, suitably rated voltage stabilizer(s) will have to be installed by the buyer, at their cost, to ensure regulated power supply to the machine.

 

The customer shall provide clean Three phase power supply to the machine, with adequate neutral point. The machine should be properly earthed with min. two earth pits (based on earth resistance value of site) so as to provide earthing resistance of less than 2 ohms. All earth pits prepared for this m/c should be interconnected with each other. The earth pit should be made as near as possible to the m/c and should not be shared with any other machine, equipment & other installations present at customer’s premises. The interconnection between earth pit & system should be made by two parallel copper strips of min. size 25×6 mm² or can be done by two parallel multi strand single core armored copper cable of min. size 95 mm².

 

 

 

LUBRICANTS

 

First fill of oil is provided as standard with the machine. However this is subject to constraints / regulations of shipping which may prevent supply of this oil.

 

The lubricants used in the system should be available with the customer before the commencement of erection and commissioning. Details of lubricants / oil required will be provided on finalization of the order.

 

AMBIENT CONDITIONS

 

Temperature  :  15 to 45°C

Relative Humidity  :  60 to 90% RH

Recommended lighting  :  250 Lux

Altitude above sea level  :  max 1000 m

 

If any of the conditions specified above not met in the production facility, customer has to notify KEESTAR Industries accordingly.

 

The production hall / plant should have continuous ventilation corresponding to the climatic condition to maintain the hall’s temperature and humidity as above.

 

The height of top most point of the Standard Tapeline is approximately 3.8 meters. It is recommended that the shed height may be chosen accordingly.

 

LAYOUT

 

The preparation of the concrete floor should have load-bearing capacity of 2.5 MT / sq. mt. And other details as per the layout provided by us.

 

UTILITIES

 

The installation of the mains electric power supply and compressed air connection should be as per our scope of supply and layout.

 

Suitable provision for lighting, transport equipment and lifting methods have to be made by the customer. The maximum weight of the case would be 3,000 kg and the maximum dimension of length, width and height of these cases would be 750 x 280 x 269 cm